E3NX-MA6 Omron 2-Channel NPN Digital Fiber Optic Amplifier

$497.08

Omron E3NX-MA6 (E3NXMA6) 2-channel digital fiber optic amplifier, 10–30 VDC NPN sinking dual outputs, wire-saving connector, featuring 100 µs response & IP50 rating.

SKU: E3NX-MA6 Category: Brand:

Description

Omron E3NX-MA6 (also known as E3NXMA6) is a dual-channel smart fiber optic amplifier from the E3NX-MA series engineered to process two independent E32-series fiber sensing heads within a single ultra-slim DIN-rail housing. Utilizing a high-intensity 625 nm red four-element LED emitter paired with Automatic Power Control (APC) and Dynamic Power Control (DPC), it delivers stable optical detection across transparent films, low-reflectivity workpieces, and high-speed targets while cutting panel footprint in half.

Integrated into PLC discrete input loops via a wire-saving master/slave bus connector, the amplifier provides two independent NPN open-collector sinking outputs alongside built-in logic functions including AND, OR, XOR, GAP, and area detection modes. Reverse-polarity and output short-circuit protection circuits, a dual white/green 7-segment LED display, and a hinged polycarbonate protective cover ensure reliable operation and IP50 ingress protection under continuous industrial vibration.

Key Features

  • Dual-Channel High-Density Housing: Integrates two independent fiber channels into a 10 × 33.5 × 75.3 mm (0.39 × 1.32 × 2.96 in) DIN-rail body.
  • Ultra-Fast Selectable Response: Configurable 100 µs (SHS), 450 µs (HS), 1 ms (Standard), or 16 ms (Giga-power) switching speeds.
  • Dual NPN Sinking Outputs: Two 10–30 VDC NPN open-collector outputs rated up to 100 mA load current with Light-ON/Dark-ON selection.
  • Smart Tuning & Built-In Logic: Supports 2-point, full-auto, position, and power tuning plus AND, OR, XOR, GAP, and timer functions.
  • Wire-Saving Bus Architecture: Gang-mounts up to 30 units with optical mutual interference prevention (up to 9 units) and reduced wiring.
  • Dual Digital LED Display: Reversible white incident-level and green threshold-level 7-segment displays protected by an IP50 polycarbonate cover.

Technical Specifications

Manufacturer Omron
Manufacturer Part Number (MPN) E3NX-MA6
Alternate Part Number E3NXMA6
Model Nomenclature / Code Breakdown E3NX = Smart Fiber Amplifier Series; MA = 2-Channel Standard Type; 6 = Wire-Saving Connector, NPN Output
Product Series E3NX-MA Series
Product Category Digital Amplifiers
Same-Series Complementary Model E3NX-MA8 (PNP Wire-Saving Connector); E3NX-MA11 (NPN 2 m Pre-Wired Cable); E3NX-MA0 (Sensor Communications Unit Type)
Sensing / Measurement Principle 2-Channel Digital Fiber Optic Amplifier (Compatible with Omron E32-Series Through-Beam & Reflective Fiber Units)
Number of Fiber Channels 2 Channels (Accepts 2 Fiber Units via Four Ø 2.4 mm (0.09 in) Fiber Ports)
Light Source & Wavelength Red 4-Element LED, 625 nm
Optical Power Stabilization Automatic Power Control (APC, Always Enabled) & Dynamic Power Control (DPC, Selectable)
Sensitivity / Threshold Adjustment Smart Tuning (2-Point, Full Auto, Position, Max Sensitivity, Power, Percentage −99% to +99%) or Manual (+/− Buttons)
Hysteresis Width Setting Standard Setting or User-Defined (0 to 9,999)
Parameter Memory Banks 4 Selectable User Banks (Banks 1 to 4)
Supply Voltage Range 10 to 30 VDC (Including 10% Peak-to-Peak Ripple)
Power Consumption (at 24 VDC) Normal Mode: ≤ 960 mW (≤ 40 mA); Eco ON: ≤ 770 mW (≤ 32 mA); Eco LO: ≤ 870 mW (≤ 36 mA)
Power Consumption (10 to 30 VDC Range) Normal: ≤ 1,080 mW (≤ 36 mA at 30 VDC, ≤ 75 mA at 10 VDC); Eco ON: ≤ 840 mW (≤ 28 mA at 30 VDC, ≤ 55 mA at 10 VDC); Eco LO: ≤ 960 mW (≤ 32 mA at 30 VDC, ≤ 65 mA at 10 VDC)
Control Output Type & Polarity 2 Independent NPN Open Collector (Sinking) Outputs (OUT1 & OUT2), 30 VDC Max Load Supply
Operation Mode / Switching Logic Light-ON / Dark-ON Selectable (via L/D Button)
Output 1 & Output 2 Logic Functions OUT1: Normal or Area Detection; OUT2: Normal, AND, OR, XOR, GAP, Falling Sync, Rising Sync, or Area Detection
Max. Load Current ≤ 100 mA per Output (1 to 3 Gang-Mounted Units); ≤ 20 mA per Output (4 to 30 Gang-Mounted Units)
Residual Voltage (Voltage Drop) ≤ 1 V (at Load Current ≤ 10 mA); ≤ 2 V (at Load Current 10 to 100 mA)
OFF-State Leakage Current ≤ 0.1 mA
Response Time (Operate / Reset) Super-High-Speed (SHS): ≤ 100 µs; High-Speed (HS): ≤ 450 µs; Standard (Stnd): ≤ 1 ms; Giga-Power (GIGA): ≤ 16 ms
Startup Waiting Time ≤ 200 ms After Power-ON
Timer Functions Disabled, OFF-Delay, ON-Delay, One-Shot, or ON-Delay + OFF-Delay (1 to 9,999 ms)
Maximum Gang-Mountable Units Up to 30 Amplifier Units (Via Wire-Saving Master/Slave Connectors)
Mutual Interference Prevention Up to 9 Units (Optical Communication; Disabled in Super-High-Speed Mode)
Ingress Protection (IP) IP50 (IEC 60529, With Protective Cover Attached)
Operating Ambient Temperature 1–2 Units: −25 to 55 °C (−13 to 131 °F); 3–10 Units: −25 to 50 °C (−13 to 122 °F); 11–16 Units: −25 to 45 °C (−13 to 113 °F); 17–30 Units: −25 to 40 °C (−13 to 104 °F)
Storage Ambient Temperature −30 to 70 °C (−22 to 158 °F) (With No Icing or Condensation)
Operating & Storage Humidity 35% to 85% RH (With No Condensation)
Ambient Light Immunity Incandescent Lamp: ≤ 20,000 lx; Sunlight: ≤ 30,000 lx (Receiver Side)
Max. Operating Altitude & Pollution Degree ≤ 2,000 m (6,561 ft); Pollution Degree 3 (Indoor Use)
Vibration Resistance (Destruction) 10 to 55 Hz, 1.5 mm (0.06 in) Double Amplitude, 2 Hours Each in X, Y, and Z Directions
Shock Resistance (Destruction) 500 m/s² (Approx. 50 G), 3 Times Each in X, Y, and Z Directions
Protection Circuits Power Supply Reverse Polarity Protection, Output Short-Circuit Protection, Output Reverse Polarity Protection
Insulation Resistance ≥ 20 MΩ (at 500 VDC)
Dielectric Strength 1,000 VAC, 50/60 Hz for 1 Minute
Connection Type Wire-Saving Connector Interface (Requires E3X-CN21 Master or E3X-CN22 Slave Connector, Sold Separately)
Max. Cable Extension Length ≤ 30 m (98.4 ft) Using ≥ 0.3 mm² (AWG 22) Conductor (24 to 30 VDC Required When Extended)
Pin 1 / Brown Wire (BN) — Master Connector E3X-CN21 +V Power Supply (10 to 30 VDC)
Pin 2 / Blue Wire (BU) — Master Connector E3X-CN21 0 V Power Supply Common (GND)
Pin 3 / Black Wire (BK) — Master Connector E3X-CN21 Channel 1 Control Output (OUT1, NPN Open Collector)
Pin 4 / Orange Wire (OR) — Master Connector E3X-CN21 Channel 2 Control Output (OUT2, NPN Open Collector)
Slave Connector E3X-CN22 Leads (2-Conductor) Black Wire: Channel 1 Control Output (OUT1); Orange Wire: Channel 2 Control Output (OUT2) (Power Bridged Internally)
Indicators / LED Display Dual 7-Segment Displays (White Main Incident Level, Green Sub Threshold Level; Reversible), OUT1/OUT2 (Orange), L/D (Orange), ST (Blue), DPC (Green), OUT1/OUT2 Selection (Orange)
Housing Style & Mounting Slim Rectangular DIN-Rail Amplifier (35 mm DIN Track Snap-On or Side Mounting Bracket)
Overall Dimensions (W × H × D) 10 × 33.5 × 71.8 mm (0.39 × 1.32 × 2.83 in) Body; 10 × 33.5 × 75.3 mm (0.39 × 1.32 × 2.96 in) With Wire-Saving Connector
Dimensions With Protective Cover Open (H × D) 104.8 mm (4.13 in) Max. Height × 147.1 mm (5.79 in) Max. Depth (170° Cover Opening Angle)
Weight Sensor Only: Approx. 20 g (0.71 oz); Packed State: Approx. 60 g (2.12 oz)
Case & Cover Material Polycarbonate (PC)
Included in Package E3NX-MA6 Fiber Amplifier Unit, Instruction Manual (Wire-Saving Connector Not Included)
Compatible Mating Accessories (Sold Separately) E3X-CN21 Master Connector (4-Core, 2 m), E3X-CN22 Slave Connector (2-Core, 2 m), E39-L143 SUS304 Mounting Bracket, PFP-100N / PFP-50N DIN Track, PFP-M End Plate, E32-Series Fiber Units

Applications

Omron E3NX-MA6 is deployed in high-density semiconductor wafer handling stages, SMT component tape feeders, and compact electronics assembly cells where two fiber optic sensing points must share minimal DIN-rail cabinet space. Its dual-channel differential and gap logic capabilities enable simultaneous edge alignment, transparent glass substrate mapping, and dual-point part presence verification on high-speed rotary indexers and vibratory bowl feeders. When paired with heat-resistant or chemical-resistant E32 fiber heads, it also monitors wet-etching baths, curing ovens, and small-part ejection chutes.